Reference library

Check the source.

Sources used in the study notes, with links to the chapters that use them. Each chapter lists the relevant sections and the official knowledge statement. Supplemental sources are labeled separately from CAB’s exam references.

[01]CAB Architects Practice Act compilation, April 2026
Used in 7 chapters
  • K1: Architects Practice Act

    The whole Act and CAB's regulations in one place: practice and services, responsible control, stamps, contracts, exemptions, licensure, discipline, renewal, business entities and conduct. BPC §§5500–5610.3, including §§5536.3, 5561, 5588 and 5600–5600.4. 16 CCR §§109, 116, 117, 121, 124, 134, 136, 140, 144, 150–152, 160, 165.

  • K4: Project requirements

    16 CCR §160(a), competence and applicable laws

  • K7: Consultant services

    BPC §5500.1(b)(3), coordination of consultants. 16 CCR §160(a), professional competence

  • K9: Risk management

    BPC §§5536.22, 5536.25–5536.27, 5588. 16 CCR §160(a)–(b)

  • K11: Owner-hired consultants

    BPC §5535.1. 16 CCR §160(a), professional competence and responsible control

  • K13: Conflict resolution

    16 CCR §160(d)(5), impartial contract interpretation and performance judgments. BPC §5536.22(a)(5), the contract must describe how additional services and changes are handled

  • K50: Applications for payment

    BPC §5536.26: certification as professional opinion rather than warranty

[13]AIA B101–2017
Used in 28 chapters
[14]CAB CSE Handbook, April 2026
Used in 45 chapters
[17]AIA C401–2017

Supplemental primary source

Used in 5 chapters
[21]AIA A201–2017
Used in 18 chapters
[22]AIA A101–2017
Used in 5 chapters
[30]AIA G714–2017

Supplemental primary source

Used in 4 chapters
[41]California Code of Civil Procedure: construction-defect outside limits
Used in 2 chapters
  • K9: Risk management

    §337.1 patent defects. §337.15 latent defects · Supplemental primary-source clarification. Not a claim that this particular page is on CAB’s exam reference list.

  • K52: Warranties & time limits

    §337 written contracts. §337.1 patent defects. §337.15 latent defects. Apply scope and exceptions · Supplemental primary-source clarification. Not a claim that this particular page is on CAB’s exam reference list.

[43]California Civil Code, Works of Improvement (Division 4, Part 6)
Used in 5 chapters
  • K13: Conflict resolution

    Works of improvement provisions (CAB-listed, sections 8000 to 9566)

  • K46: Liens & payment protection

    Private-work design-professional/mechanics liens, preliminary notice (§8204), completion (§8180), notice of completion (§§8182, 8190), recording (§§8412, 8414), stop payment notices. Public works: stop payment notice timing (§9356) and payment bonds (§9550) · CAB expressly lists Division 4, Part 6. Statutory remedies and applicable conditions. Not a complete filing manual.

  • K47: Changes during construction

    §8850 Private Works Change Order Fair Payment Act (contracts entered on or after January 1, 2026): 30-day owner written response, 60-day payment of undisputed amounts, meet-and-confer/mediation, and stop-work rights (non-mixed-use residential up to four stories exempt) · CAB-listed Civil Code Part 6 (sections 8000–9566).

  • K50: Applications for payment

    Private works retention: §8811 5% retention cap (non-mixed-use residential up to four stories exempt), §8812 owner release within 45 days, §8814 contractor pass-through to subcontractors within 10 days · CAB-listed Civil Code Part 6 (sections 8000–9566). Public works retention is in Public Contract Code §§7107 and 7201.

  • K51: Project close-out

    Notice of completion and shortened mechanics-lien recording periods · CAB expressly lists Division 4, Part 6. Statutory remedies and applicable conditions. Not a complete filing manual.

[62]LCI: Environmental document submission

Supplemental primary source

Used in 1 chapter
  • K21: CEQA

    Current NOD/NOE filing: local NODs and NOEs to county clerk and LCI (State Clearinghouse). SB 69 effective January 1, 2024 · Supplemental clarification of current notice filing. Not a separate CAB-listed exam reference.

[100]2025 California Building Code
Used in 6 chapters
  • K33: Integrating building systems

    Chapter 16, Structural Design. Chapter 17, Special Inspections and Tests · Use the adopted edition and project-specific structural criteria.

  • K34: Evaluating materials

    Chapter 12, Section 1206. Airborne and structure-borne sound between dwelling units · Use the adopted edition and local amendments.

  • K41: Working with regulatory agencies

    Chapter 1, Section 1.10.1: the hospital agency (HCAI, formerly OSHPD) enforces DSA's access rules and the State Fire Marshal's rules on hospitals · Supplemental locator. CAB's named chapter subset does not specifically include Chapter 1.

  • K43: Resolving agency conflicts

    Chapter 1: applicable agency administration, interpretation, and alternative methods · Verify the exact applicable provision. No blanket hierarchy is asserted.

  • K48: Construction change documents

    Chapter 1: responsible design professional and amended construction documents · Supplemental locator. CAB's named chapter subset does not specifically include Chapter 1.

  • K49: Deferred submittals

    Chapter 1: phased approval and deferred-submittal procedures · Supplemental locator. CAB's named chapter subset does not specifically include Chapter 1.

[101]ASTM C423

Supplemental primary source

Used in 1 chapter
  • K34: Evaluating materials

    Sound absorption and room-acoustic testing. Noise Reduction Coefficient (NRC). · Supplemental technical clarification. Not a separate CAB-listed exam reference.

[102]ASTM E413

Supplemental primary source

Used in 1 chapter
  • K34: Evaluating materials

    Rating sound insulation. Sound Transmission Class (STC) and limits of a single-number rating. · Supplemental technical clarification. Not a separate CAB-listed exam reference.

[138]CAB-listed California Administrative Code: DSA structural safety
Used in 3 chapters
  • K48: Construction change documents

    Chapter 4: construction changes to DSA-approved documents (CCD Category A and B) and the design professional in general responsible charge

  • K49: Deferred submittals

    Chapter 4: deferred submittals on DSA-approved projects

  • K54: State inspections & reports

    Chapter 4: design-professional, inspection, and reporting duties · CAB currently links the 2022 publication. Current DSA administrative guidance was separately checked. Do not label this link the 2025 edition.