K35 — Site hazards
California sites come loaded with geological, wildfire, wind, flood, and legacy-soil surprises, yet every hazard follows the exact same four-step exam choreography. A hazard map flags the question, a specialist study answers it for that parcel, and design development drawings show the architectural fix. The owner hires and pays for site studies, consultants write them, the architect weaves their findings into the design, and the agency approves the solution before issuing a permit.
Seismic activity
The Seismic Safety Commission studies earthquakes and recommends risk-reduction policy, while the California Geological Survey (CGS) maps geologic and seismic hazards across the state.
| Hazard | What happens |
|---|---|
| Ground shaking | Moving earth loads the structure, causing more than 90% of earthquake damage |
| Fault rupture | Ground tears and offsets right along a surface fault |
| Liquefaction | Loose, saturated sandy soil loses strength and behaves like quicksand, sinking or tilting foundations |
| Landslide | Shaking shakes loose soil and rock down a slope |
| Lateral spreading | Soil fractures into blocks that slide apart |
| Tsunami and dam failure | Inundation floods low-lying areas |
A fault is a fracture in Earth's crust where rock has shifted across the break, and the fault trace is where that fracture reaches the surface.
Which map does what
Each seismic hazard gets its own map, meaning a shaking map never answers a fault-rupture question.
| Map | What it means for the project |
|---|---|
| Earthquake Fault Zones (Alquist-Priolo, CGS) | Fault investigation and report by a licensed geologist before permit |
| Seismic Hazard Zones for liquefaction and landslides (CGS, Seismic Hazards Mapping Act) | Site-specific geotechnical report approved by the city or county before permit |
| Ground shaking (U.S. Geological Survey data) | Sets design ground motion feeding the seismic design category |
| Tsunami hazard areas (CGS) | Evacuation planning, plus California Building Code (CBC) tsunami design for Risk Category III and IV buildings in a Tsunami Design Zone |
Alquist-Priolo fault zones
- The Alquist-Priolo Earthquake Fault Zoning Act bars buildings for human occupancy from straddling the surface trace of an active fault (one that ruptured within about the last 11,000 years). It governs surface rupture only, not shaking.
- Mapped zones average about a quarter mile wide.
- Before issuing a permit, the city or county requires a geologic investigation for land divisions and most human-occupancy buildings inside the zone. A licensed geologist conducts the study and writes the report.
- State law exempts a single-family wood- or steel-frame house up to two stories that isn't part of a development of four or more, though local agencies can be stricter.
- The zone boundary is neither the fault line nor a setback. It simply marks where a study is required so the geologist can locate actual traces.
- If the study finds an active trace, the building stays off it, set back generally 50 feet from the trace unless the geologist justifies another distance.
The Seismic Hazards Mapping Act works on the same rhythm for liquefaction and landslides: a certified engineering geologist or registered civil engineer investigates, the city or county approves the report before permit, and fixes like ground improvement or deeper foundations move straight into the drawings.
Seismic design category
Older codes ranked shaking by seismic zones 1 to 4 (Zone 4 worst). Current codes split the logic in two:
- Risk category (I to IV) measures the consequence of failure: most buildings are II, schools and crowds are III, and essential facilities like fire stations and hospitals are IV (K25).
- Seismic design category (SDC) runs A to F and comes from the risk category plus expected site shaking, which depends on soil conditions in the geotechnical report (never building height). Most of California lands in D or higher.
Higher SDCs demand tougher detailing and heavier nonstructural bracing. From category C upward, the geotechnical report must address slope stability, liquefaction, and surface rupture whether the site sits in a mapped zone or not.
Asked to pick "the seismic concerns" on an exam item? Look for soil and foundation, nearby faults, lateral system, SDC, and nonstructural bracing (utility hookups and solar orientation belong to general site planning, not seismic).
Building response to shaking
- Compared with the floors above, a story can be soft (lacking sideways stiffness) or weak (lacking strength), or both at once.
- Classic soft story: an airy ground floor of storefront glass or tuck-under parking carrying stiffer apartment floors above, forcing sideways drift to pile into that ground level.
- Shear walls bunched to one side twist the building (torsion), and walls that fail to stack floor to floor snap the load path.
- Re-entrant corners (inside corners of L-, T-, and U-shaped plans) concentrate stress and call for a seismic joint or extra strength.
- Lock in the lateral system with the structural engineer early during schematic design and design development.
- Ceilings, ducts, pipes, light fixtures, and equipment need their own seismic bracing even when the frame complies.
- Older unreinforced masonry shakes badly and falls under the Existing Building Code (Title 24, Part 10).
Fire hazard
Three agencies divide California wildfire duties: the California Department of Forestry and Fire Protection (CAL FIRE) maps Fire Hazard Severity Zones (FHSZ), the Office of the State Fire Marshal writes wildfire building standards, and the Board of Forestry and Fire Protection designates the State Responsibility Area and writes defensible space rules.
- The State Responsibility Area (SRA) is mostly unincorporated land under state wildland fire protection, while the Local Responsibility Area (LRA) is protected by local fire agencies.
- Mapped severity comes in three zones: Moderate, High, and Very High.
- CAL FIRE's model weighs two key elements: probability of burning and expected fire behavior.
- Low humidity and wind accelerate ignition, fire races uphill faster, and wind-blown embers flying a mile ahead of the flames ignite most buildings.
- Hazard describes the land while risk includes the building and its defenses. Hardening a building lowers its risk without changing the mapped hazard zone.
- Cities and counties adopt CAL FIRE maps by ordinance: they may add areas, never downgrade a state rating.
Wildland-Urban Interface Code
The California Architects Board (CAB) lists both the Wildland-Urban Interface (WUI) Code (Title 24, Part 7) and the California Fire Code's WUI rules (Part 9), yet every wildfire rule now lives inside Part 7: the former CBC Chapter 7A construction rules, fire-safe access roads, water supply, signage, defensible space, and fuel modification. CBC Chapter 7A and Fire Code Chapter 49 now simply point straight to Part 7. Construction rules govern new buildings in any mapped Fire Hazard Severity Zone and any locally designated WUI area.
Key ignition-resistant package:
- Class A roof (top fire rating)
- Ember- and flame-resistant vents (WUI vents) at attics, eaves, and crawl spaces
- Noncombustible or ignition-resistant exterior wall coverings
- Protected eaves and soffits
- Multipane windows with at least one tempered pane, or fire-rated glazing
- Ignition-resistant or noncombustible decks
Stucco walls won't save an attic fed embers through a cheap screen vent, making the full exterior envelope a single system. The California Supplemental Examination (CSE) sample wildfire question pairs noncombustible exterior finishes with defensible space (skip answers relying on roof sprinklers or wood fences).
Defensible space
Defensible space clears flammable vegetation and debris around a building to starve approaching flames. State law requires 100 feet of defensible space from the building, or to the property line if closer.
| Zone | Distance | What happens there |
|---|---|---|
| Zone 1 | Up to 30 feet | Clear dead plants, leaves, and roof or gutter debris. |
| Zone 2 | 30 to 100 feet | Keep grass short. Space shrubs and trees apart. |
The owner maintains defensible space after move-in. On the site and landscape plans, the architect delineates both zones, specifies noncombustible paving right against the building instead of bark mulch or a wood fence, and pulls planting back from vents and windows.
Wind hazard
- Strong wind drives uplift and overturning, not just horizontal push.
- Exposure categories rank terrain openness: Exposure B is urban, suburban, or wooded, C is open terrain with scattered obstructions, and D is flat, unobstructed land or water (Exposure A was retired years ago).
- Basic wind speed comes from CBC wind maps for the site and risk category. In special wind regions (mountain passes and canyons), the building department sets higher local speeds.
- Wind still governs roof edges, overhangs, cladding, glazing, and rooftop equipment even when seismic governs the frame.
- The engineer checks wind and seismic separately and designs the frame for whichever governs, never adding them together.
Flood zones
- The Federal Emergency Management Agency (FEMA) publishes Flood Insurance Rate Maps (FIRMs) establishing 100-year floodplain boundaries. A 100-year flood carries a 1% chance in any given year: flooding last winter buys you zero immunity, not 99 dry years.
| FIRM zone | What it means |
|---|---|
| A or AE | 1% annual chance flood along rivers and lakes. AE adds a base flood elevation (BFE). |
| V or VE | Coastal wave zone: elevate buildings on piles with only breakaway walls below. |
| X | Moderate (500-year) or minimal flood risk |
- The local floodplain administrator enforces flood ordinances alongside CBC flood-resistant construction. Set the lowest floor at or above BFE (nonresidential buildings may instead dry floodproof below it).
- Protect equipment, utilities, access, and drainage too: raising the lobby floor accomplishes little if the switchgear and generator drown in the basement. Add sewer check valves and waterproof basement walls.
- Even Zone X lots below a recently burned hillside can flood violently. Check FEMA maps and the county flood control district early, before freezing the site plan.
Question
A parcel sits inside an Alquist-Priolo fault zone. Can the architect use the zone line as the building setback?
Hazardous materials
- Common culprits include former industrial sites, gas stations, underground tanks, landfills, dry-cleaner solvents, asbestos, and lead. A leaking underground fuel tank's primary threat is groundwater.
- The owner arranges testing, and environmental specialists plan remediation.
- Two basic cleanup strategies: remove and dispose under federal, state, and local rules, or encapsulate in place.
- The Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), better known as Superfund, governs major contaminated-site cleanups. Brownfields are properties stalled from reuse by real or suspected contamination, and not every brownfield is a Superfund site.
Contamination and combined hazards
- A Phase I environmental site assessment reviews historic records, interviews people, and inspects the site, normally without sampling. Any red flag triggers a Phase II for targeted sampling.
- Soil bearing strength and soil contamination require separate investigations, even on the same lot.
- Hazards stack: burned hillsides trigger floods and slides, and floodwater spreads site contamination.
- Along the coast, the California Coastal Act expects new development in hazard areas to stay stable without seawalls (K22).
Watch the three recurring exam traps across this whole chapter: treating the fault-zone edge as a setback, expecting a hardened house to downgrade its fire zone, and elevating the floor while leaving switchgear underwater.
K35 / Quick check
Quiz
TLDR · Quick Reference
- Investigate first
- Maps flag the question, the owner hires the specialist to answer it for the site, and design development drawings show the fix.
- Fault zones
- Under the Alquist-Priolo Act, no building for human occupancy crosses an active fault (ruptured within about 11,000 years). A licensed geologist's report comes first, with a typical 50-foot setback.
- Seismic Hazard Zones
- Liquefaction and earthquake-induced landslide zones require a site-specific geotechnical report approved by the city or county before permit.
- Seismic design category
- Runs A to F from risk category plus expected site shaking (including soil), replacing old seismic zones 1 to 4.
- Soft vs. weak story
- Soft lacks sideways stiffness, weak lacks strength, and one story can be both.
- Wildfire
- The California Department of Forestry and Fire Protection (CAL FIRE) maps Moderate, High, and Very High Fire Hazard Severity Zones. Hardened exteriors plus 100 feet of defensible space cut risk without changing the mapped zone.
- Wind
- Watch uplift, overturning, and attachments across Exposure B, C, and D. The engineer designs the frame for wind or seismic, whichever governs.
- Flood and contamination
- A 100-year flood is a 1% chance every year (protect equipment too). Phase I reviews records, Phase II samples, and the owner arranges testing.
Student Q&A
Questions students asked about K35, with answers from The Exit Club. All questions
Loading questions…
Something in K35 unclear? Log in to ask a question.
Log in to askYour questions
Sources & handbook wording
K35 · Knowledge of methods for identifying and evaluating the implications of special conditions on design and construction (e.g., seismic zones, fire severity zones, flood zones, wind).
- CAB CSE Handbook, April 2026 ↗
K35 scope statement only. Detailed technical requirements supported separately
- CBC 2025 Chapter 16 ↗
Wind, seismic and other design loads
- California Fire Code 2025 ↗
Applicable fire-area, access and protection requirements
- DTSC: Site Mitigation and Restoration Program ↗
Contaminated-site investigation and cleanup oversight. Identify the applicable program · Supplemental primary-source clarification. Not a claim that this particular page is on CAB’s exam reference list.
- Supplemental primary source: USGS: 100-Year Flood: It’s All About Chance ↗
General Information Product 106. One-percent annual exceedance probability and repeated floods
- 2025 California Wildland–Urban Interface Code ↗
Wildland–urban interface construction requirements
- Supplemental primary source: California Geological Survey: Alquist-Priolo Earthquake Fault Zones ↗
Fault zone maps and the geologic investigation requirement
- Supplemental primary source: California Geological Survey: Seismic Hazard Zones ↗
Liquefaction and landslide zone maps
- Supplemental primary source: Office of the State Fire Marshal: Fire Hazard Severity Zones ↗
Fire hazard severity zone maps
- Supplemental primary source: California Public Resources Code §4291 ↗
100 feet of defensible space in the State Responsibility Area
- Supplemental primary source: State Fire Marshal: Part 7 emergency regulation express terms ↗
Readopted emergency rule setting the scope of the Wildland-Urban Interface Code